DBAC DBAC DBAC DBAC
  • Dansk BørneAstma Center
    • Om DBAC
    • Beliggenhed
    • Fonde og donationer
    • Persondatapolitik
  • Børneastma
    • Generelt om astma hos børn
    • Asthma hos små børn
    • Astma hos større børn
    • Generel astma behandling
    • Astmabehandling småbørn
    • Astmabehandling større børn
    • Undersøgelser
    • Gode råd
    • Litteratur til forældre
  • Allergi og eksem
    • Generelt om allergi
    • Mælkeallergi
    • Generelt om eksem
  • Kliniske studier
    • COPSAC 2010 (ABC)
    • COPSAC-Severe
    • COPSAC Acute (Antibiotika)
  • Video

Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.

    Home Publications Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.
    NextPrevious

    Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 18 september, 1984 | 0

    J Invest Dermatol. 1984 Sep
    Bisgaard H, Kristensen JK.

    Abstract
    The cutaneous microcirculation is a desirable model for pharmacologic and physiologic studies of inflammatory mediators. For exact measurements of the induced blood flow changes, two objective methods are introduced. The laser-Doppler flowmeter and the 133Xe washout technique have formerly been used for measurement of the undisturbed cutaneous blood flow. We have modified these methods to measure changes in the blood flow following intracutaneous deposition of a vasodilator, leukotriene D4. When compared with a metric estimate of the erythemal response, the two new methods were found to be more sensitive than the traditional estimate of cutaneous blood flow changes. Both methods exhibited a good sensitivity and reproducibility when applied simultaneously, although the 133Xe washout technique appeared to be able to separate interindividual differences that could not be recognized by the laser-Doppler technique. Even though the laser-Doppler technique is superior in simplicity of use, the 133Xe washout technique is recommended for exact measurements.

    PMID: 6470522

    No tags.
    NextPrevious


    KONTAKT

    DBAC
    Dansk BørneAstma Center
    Herlev og Gentofte Hospital
    Telefon +45 3867 7360
    kontakt@dbac.dk
    DBAC • Herlev og Gentofte Hospital • Danmark © 2023
    • 20200227-P4-morgen-Rikke
    • Astma hos skolebørn
    • Astma hos små børn (Bisgaard)
    • COPSAC Acute (Antibiotika)
    • COPSAC informationsaften
    • COPSAC-Severe
    • Dansk BørneAstma Center
      • ABC-DK
      • Forebyggelse
      • Forskning
      • Forskningscentre
      • Generelt om allergi
      • Generelt om eksem
      • Input fra COPSAC familier
      • Knud har tabt pusten
      • Metoder
      • Nyheder
      • Om astma
        • Generel astma behandling
          • Astmabehandling småbørn
          • Behandling af astma hos større børn
        • Generelt om astma hos børn
          • Asthma hos små børn
          • Astma hos større børn
        • Gode råd
        • Undersøgelser
      • Om DBAC
        • Beliggenhed
        • Bestyrelsen
        • Fonde
        • Hjælp os med at hjælpe
        • Jobs
        • Kontakt
        • Litteratur til forældre
        • Patient- og lægeorganisationer
        • Persondatapolitik
        • Sponsorer
      • Spil
      • Undersøgelser
      • video
    • FAVORIT
    • Forebyggelse af astma hos børn (TEST-tilmelding)
    • Forebyggelse af astma hos børn (TEST)
    • Hans Bisgaard
    • Hans Bisgaard nekrolog
    • Indeklima og sundhed på Bellahøj
    • Lokale steroider for børn med astma
    • Mælkeallergi
    • myter og fakta om børneastma
    • Persondatapolitik
    DBAC